IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Power Distribution Cables

600/1000V Twisted pairs shielded Type P signal cables

Construction

Conductor: Stranded copper conductor tin or alloy coated where necessary for the application , conductor per

ASTM or IEC 60228.

Separator tape: optional

Insulation:

Cross-linked polyolefin(XLPO)according to IEEE 1580 2010 Type P,Type X, E, T, T/N, S, P, LSX and LSE as option.

Shielding: optional

Jacket:

Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or TPO

jacket as option (optional for Type P with HD thicknesses).

Armor: optional and shall be nonmagnetic

Sheath: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P

or TPO sheath as option (optional except for tinned copper braid armoured cables).

Optional: For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO

jacket/sheath.

Table B.13—Typical dimensions and weights; paired shielded signal cable 600/1000 V;Type P cables


Number
of pairs
Conductor
AWG size
Unarmored Armored Armored
and sheathed
Nom. dia. (in) Approx.
weight (lb/1000 ft)
Nom. dia.
(in)
Approx.
weight (lb/1000 ft)
Nom.
dia. (in)
Approx.
weight
(lb/1000 ft)
Individual and overall aluminum/polyester tape shields
1 18 0.392 63 0.442 123 0.607 176
2 18 0.551 131 0.601 204 0.766 335
3 18 0.581 163 0.631 265 0.796 343
4 18 0.63 195 0.68 317 0.845 410
5 18 0.685 243 0.735 395 0.9 511
7 18 0.742 340 0.792 457 0.957 575
8 18 0.8 388 0.85 521 1.015 752
10 18 0.933 495 0.983 699 1.148 874
12 18 0.962 581 1.012 780 1.177 982
16 18 1.066 748 1.116 833 1.281 1182
18 18 1.123 824 1.173 1050 1.338 1300
24 18 1.314 1069 1.364 1151 1.529 1720
1 16 0.412 77 0.462 120 0.627 203
2 16 0.585 160 0.635 249 0.8 377
3 16 0.617 200 0.667 311 0.832 410
4 16 0.671 239 0.721 389 0.886 569
5 16 0.73 297 0.78 483 0.945 609
7 16 0.792 416 0.842 559 1.007 703
8 16 0.856 475 0.906 638 1.071 803
10 16 1 606 1.05 787 1.215 1098
12 16 1.032 711 1.082 923 1.247 1138
16 16 1.145 948 1.195 1231 1.36 1517
18 16 1.207 1100 1.257 1260 1.422 1570
24 16 1.415 1510 1.465 1625 1.63 2065
1 14 0.408 97 0.458 151 0.589 199
2 14 0.601 202 0.651 315 0.818 515
4 14 0.698 301 0.748 469 0.921 633
5 14 0.764 374 0.814 608 0.987 787
7 14 0.876 480 0.926 704 1.099 886
8 14 0.947 550 0.997 803 1.17 1011
10 14 1.109 747 1.159 1003 1.332 1196
12 14 1.145 896 1.195 1203 1.368 1434

NOTE—These values are for reference purposes only and should not be construed as requirements. Weights of armored constructions are based on bronze braid armor. It is recommended that the user/specifier contact the manufacturer for manufacturer specific values.